For homes where the ceiling is substantially higher you can also buy extension rods lower fans although as a rule of thumb it s probably.
Minimum height for ceiling fan australia.
The exception is a kitchen laundry hallway or corridor where height can be a minimum height of 2100mm.
Habitable room legal ceiling height in queensland is as follows.
To extend old eight foot ceilings in a remodel aim.
From the blades to the floor and that more is better.
A room or space within a building must have sufficient height suitable for the intended function of that room or space.
The standard installation height for ceiling fans is at least 2 1m from the floor to the blades of the fan and at least 300mm from the ceiling.
Here s how to choose a ceiling height that s right for you.
For new flat coffered tray or sloped ceilings go for a minimum of nine feet.
It has 6 available speed options to control the airflow of the fan and reversible from the remote are settings for both summer and winter use.
While not ideal there are many houses with both 8 ft.
The standard ceiling height in australia is 2 4 metres.
However there are a lot of people who are willing to pay extra for a 2 55m 2 7m or even 3m ceilings.
According to the building code of australia bca there are certain minimum height regulations.
Ceilings and ceiling fans.
The standard ceiling height for most houses in australia is 2 4m.
That said i couldn t find a code reference for a minimum ceiling fan height from the floor.
The bca sets out the minimum ceiling heights for different rooms.
Online sources say there should be at least 7 ft.
According to the building code the standard ceiling height in australia is 2 4 metres for habitable rooms.
For non habitable rooms the standard ceiling height starts at 2 1 metres.
So what are the issues.
As a result you can t choose to go lower than these requirements laid down by this code.
According to bca vol 2 part 3 8 2 for the requirement to be satisfied the ceiling height must not be less than.
Follow the manufacturer s instructions and choose a low.
What is the standard ceiling height in australia.
The habitable rooms are the areas of the house that are occupied by people to do various activities.
In a kitchen laundry or the like 2 1m and.
The energy efficient irene 3 ceiling fan now comes in a low profile version maintaining its unique minimal design to suit those spaces with a lower ceiling height.
For building class 1 2 3 a habitable room must have a minimum height of 2400mm.
However you can pay extra for it to be higher at 2 55m 2 7m or 3m when building.
Most builders will normally provide a 2 4m ceiling height as standard.