210170 test equipment pdf manual download.
Megger insulation tester manual.
Lead integrity can be.
If you are testing insulation resistance to ground place the positive probe on the ground wire or the grounded metal junction box and the negative probe on the conductor or terminal.
Make sure the circuit is not reenergised whilst the instrument is connected.
Megger insulation testers combine safety with durability developed after extensive customer research specifically to meet the needs of today s electrical contractors the new mit300 range of insulation and continuity testers from megger is not only durable and easy to use but also incorporates a comprehensive set of features designed to.
Megohmmeter insulation testers whether you work on motors generators cables or switch gear the fluke digital insulation resistance testers provide noise free reliable results.
View and download megger 210170 user manual online.
Mj159 mj359 mj559 mj459.
Data sheet mit510 2.
Megger device usb drivers.
Usb drivers for a range of megger products.
The insulation condition from values that are only relative.
Mj160 test equipment pdf manual download.
Insulation low resistance tester.
User guide mit510 2.
Mit510 2 5 kv insulation resistance tester.
Data sheet test leads for 5 k v and 10 k v testers.
The megger mit300 series insulation resistance tester measures insulation resistance voltage and continuity in electrical installations building maintenance and electrical testing.
The average sensing meter provides accurate readings when measuring linear loads where the current or voltage has a sinusoidal waveform.
Only 15 kv rated megger test leads with plug inserts of 75 mm must only be used on the mit1525.
The megger insulation tester is a small portable instrument that gives you a direct reading of insulation resistance in ohms or megohms.
Continue with this testing procedure until you have values for all the spaces of your table.
With advanced performance the insulation tester line is designed to be safe simple to use and gimmick free.
1 2 mb 19 08 20.
The circuit under test must be switched off de energised isolated and checked to be safe before insulation test connections are made.
The mit2500 insulation and continuity tester has been designed for motor and cable testing specialist applications and electrical testing applications where operation voltages exceed 1000 v and higher insulation test voltages are needed.
For good insulation the resistance usually reads in the megohm range.
View and download megger mj160 user manual online.
Read the value of the resistance at the end of the minute test and note it in your table.